Imrt interplay effect
Witryna1 sty 2011 · The interplay effect does not result in unexpected dose variation, and the dose gradient at the edge of the PTV, obtained from dynamic measurement, agreed within 1 mm compared with static-convolved measurement. ... An experimental investigation on intra-fractional organ motion effects in lung IMRT treatments. Phys … WitrynaIMRT, respiratory motion. I. I NTRODUCTION This study investigated the possible interplay effects aris-ing from the treatment of moving targets using the DCAT (dynamic conformal arc therapy) radiotherapy technique. Interplay effects, including dose blurring (also called “dose smoothing” or the “dose gradient effect”) and local-
Imrt interplay effect
Did you know?
Witryna23 lis 2024 · Several studies further investigate the effects of regular breathing motion and collimator speed on the outcome of MLC treatments (Court et al 2008, 2010 ), showing that non-negligible interplay effects increase with target magnitude, plan complexity and breathing period. Witryna•The combination of dose blurring and interplay effects resulted in reductions in the mean dose (compared to static delivery, with deep breath motion) ranging from: •2.6 to 7.4% for enhanced dynamic wedge •1.2 to 2.5% for field-in-field •0.9 to 4.0% for IMRT •Analysis of interplay patterns suggested effects started to wash
WitrynaReceived 12 December 2005; accepted 19 July 2006 Intrafraction organ motion during the dynamic delivery of intensity-modulated radiation therapy (IMRT) treatment of lung … Witryna1 sty 2004 · Effects on dynamic (IMRT) delivery (interplay effects) In general, there is some variation of the dose at each voxel around the average blurred value. This …
Witryna21 kwi 2012 · We have developed a treatment reconstruction simulation computer code that accounts for interplay effects by combining multileaf collimator controller log … Witryna28 lis 2006 · Intra-fraction organ motion during the dynamic delivery of IMRT treatment of lung tumors may cause unexpected hot/cold spots even within the target volume, due …
Witryna1 mar 2016 · The IMRT and VMAT treatment had prescription dose of 200 cGy per fraction. The dosimetric impact due to interplay effect during IMRT and VMAT …
how to replace pool tileWitryna2 kwi 2012 · Using linac log files, real-time position management log files and 4DCT, we showed that the IMRT interplay effect caused a single fraction dose to differ from the … north belfast news death noticesWitryna21 kwi 2012 · Respiratory motion may lead to dose errors when treating thoracic and abdominal tumours with radiotherapy. The interplay between complex multileaf collimator patterns and patient respiratory motion … north belfast psni facebookWitryna6 kwi 2024 · Interplay effects, however, occur only for dynamic treatment techniques such as IMRT, VMAT and IMPT, where there is a simultaneous movement of machine parts (for example the multileaf collimators (MLC)) and the target volume, resulting in hotspots and coldspots in the dose distribution. how to replace pool table bumper feltWitryna2 gru 2016 · The purpose of this study was to evaluate the impact of the motion interplay effect in early-stage left-sided breast cancer intensity-modulated radiation … how to replace pool table clothWitryna26 paź 2024 · One study found significant changes in target coverage for highly modulated fields and large motion amplitude 10 while another reported minimal interplay even as target excursion increased to 2–3 cm. 11 A third study reported that interplay effects would be insignificant with sufficient margin. 12 Another reported negligible … north belfast business centreWitrynaSome authors have raised concerns regarding the effect of breathing motion on IMRT dosimetry due to the ‘interplay’ effect. However, Richter et al. 17 demonstrated that when delivered over a number of fractions the dose gradient is blurred, resulting in a delivered dose that is at least equivalent to if not better than the planned dosimetry. north belfast news newspaper